LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Usefulness of water pressure observation in detection and direct clipping of source of colonic diverticular bleeding

Photo from wikipedia

Colonic diverticular bleeding is the most common cause of bleeding in the lower gastrointestinal tract [1]. Endoscopic identification of stigmata of recent hemorrhage (SRH), such as active bleeding, adherent clot,… Click to show full abstract

Colonic diverticular bleeding is the most common cause of bleeding in the lower gastrointestinal tract [1]. Endoscopic identification of stigmata of recent hemorrhage (SRH), such as active bleeding, adherent clot, or visible vessel, is important but often difficult [2, 3]. The waterjet scope, the use of which has been reported to be an independent predictive factor for identifying SRH, is primarily used to wash away feces or clots inside the diverticulum [4]. Herein, we describe a useful case of water pressure observation for the detection of SRH and endoscopic direct clipping of diverticular bleeding. A 75-year-old man with hematochezia had undergone repeated colonoscopies. Multiple diverticula were observed in the right colon, but spontaneous hemostasis prevented the identification of bleeding points. Therefore, the patient was transferred to our hospital. He developed hematochezia again 2 days later. We performed an urgent colonoscopy with bowel preparation. We used a colonoscope with waterjet function (PCF-H290TI; Olympus Medical Systems, Tokyo, Japan). We attached a super-soft transparent hood without slits (Space adjuster; TOP, Tokyo, Japan). Fresh blood and multiple diverticula with hemostatic clips applied by a previous physician were observed in the right colon; however, the bleeding stopped spontaneously (▶Fig. 1 a). We placed the tip hood of the scope in close contact with each diverticulum and inflated it with water. The water pressure opened the diverticulum, which facilitated observation of the interior. We detected a pulsating visible vessel within a diverticulum in the ascending colon (▶Fig. 1b). Although the diverticulum could not be inverted, we inflated it with water to create a working space that allowed direct pinpoint clipping with a shortarmed hemostatic clip (HX-610-135XS; Olympus) (▶Fig. 2, ▶Video 1). The patient was discharged without additional intervention. The patient had no rebleeding during the 2-month followup period. E-Videos

Keywords: water; diverticular bleeding; water pressure; observation

Journal Title: Endoscopy
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.