BACKGROUND Superficial temporal vessels have been used successfully as recipient vessels for head and neck reconstruction. This study evaluates the impact of several treatment variables on flap failure and take-back… Click to show full abstract
BACKGROUND Superficial temporal vessels have been used successfully as recipient vessels for head and neck reconstruction. This study evaluates the impact of several treatment variables on flap failure and take-back rate when using these recipient vessels. METHODS We conducted a retrospective study of all microsurgical reconstructions using superficial temporal vessels as recipient vessels in a period of 10 years. Variables collected included previous treatments (radiotherapy, chemotherapy, neck dissection, free flap reconstruction), type of flaps used (soft tissue, osteocutaneous), and vessel size discrepancy between donor and recipient vessels. RESULTS A total of 132 patients were included in the study. The flap success rate was 98.5%. The take-back rate was 10.6%. The most frequent reason for take-back was venous congestion secondary to thrombosis. None of the studied variables was associated with flap failure. Reconstructions using osteocutaneous flaps and vein diameter discrepancy (ratio ≥ 2:1) had significantly higher take-back rates. CONCLUSION Flaps with a significant size discrepancy between donor and recipient veins (ratio ≥ 2:1) and fibula flaps (compared with soft tissue flaps) were associated with a higher risk of take-back. It is crucial to minimize venous engorgement during flap harvest and anastomosis, and limit vein redundancy during flap in-setting.
               