AbstractA numerical protocol was developed for the evaluation of the passive earth-pressure coefficients (Kpq) for the case of an inclined rigid wall retaining an inclined cohesionless backfill loaded with a… Click to show full abstract
AbstractA numerical protocol was developed for the evaluation of the passive earth-pressure coefficients (Kpq) for the case of an inclined rigid wall retaining an inclined cohesionless backfill loaded with a uniform surcharge. The shape of the proposed failure surface is assumed to be a complete log-spiral. The methodology developed herein uses Kotter’s equation, which enables the computation of soil reactive pressure distribution and the resultant soil reaction on the failure surface. Furthermore, all three limit-equilibrium conditions are effectively utilized to identify the unique failure surface for the given parameters, viz, soil frictional angle (ϕ), wall frictional angle (δ), wall inclination angle (λ), and sloping backfill angle (i). Design tables are also presented for several combinations of ϕ, δ, λ, and i. For validation, the Kpq values obtained are compared with those reported by several other researchers and are found to be in good agreement with most of the available theoretical solutions.
               
Click one of the above tabs to view related content.