LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Experimental measurements of the RF sheath thickness with a cylindrical Langmuir probe

Photo by m2creates from unsplash

The small layer oscillating in front of a radio frequency (rf) biased electrode in an asymmetric rf plasma discharge without a magnetic field is diagnosed using an rf compensated cylindrical… Click to show full abstract

The small layer oscillating in front of a radio frequency (rf) biased electrode in an asymmetric rf plasma discharge without a magnetic field is diagnosed using an rf compensated cylindrical probe. Thanks to this probe (0.15 mm in diameter), the floating potential is measured in this area. Radio frequency plasmas and sheath properties are then derived from the I-V characteristics measured by the probe at different rf power levels in both capacitive and direct couplings. In direct coupling, the plasma biasing is, as expected, nearly equal to the applied rf potential except at high power levels for which the current collected by the electrode saturates and the sheath potential gap is reversed. In capacitive coupling, the self-biasing of the electrode is strongly negative due to the matching box used. From the difference between the plasma potential and the floating potential, we found a sheath thickness of about 3 λDe. Within the rf power scan performed, the sheath thicknesses deduced from the potential and density profiles are 3 times higher than those from the Child–Langmuir law both in direct and capacitive coupling in a low collisional helium plasma.The small layer oscillating in front of a radio frequency (rf) biased electrode in an asymmetric rf plasma discharge without a magnetic field is diagnosed using an rf compensated cylindrical probe. Thanks to this probe (0.15 mm in diameter), the floating potential is measured in this area. Radio frequency plasmas and sheath properties are then derived from the I-V characteristics measured by the probe at different rf power levels in both capacitive and direct couplings. In direct coupling, the plasma biasing is, as expected, nearly equal to the applied rf potential except at high power levels for which the current collected by the electrode saturates and the sheath potential gap is reversed. In capacitive coupling, the self-biasing of the electrode is strongly negative due to the matching box used. From the difference between the plasma potential and the floating potential, we found a sheath thickness of about 3 λDe. Within the rf power scan performed, the sheath thicknesses deduced from the potential and...

Keywords: plasma; sheath thickness; probe; floating potential; radio frequency; power

Journal Title: Physics of Plasmas
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.