LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Orientation-dependent indentation response of helium-implanted tungsten

Photo by cdc from unsplash

A literature review of studies investigating the topography of nano-indents in ion-implanted materials reveals seemingly inconsistent observations, with report of both pile-up and sink-in. This may be due to the… Click to show full abstract

A literature review of studies investigating the topography of nano-indents in ion-implanted materials reveals seemingly inconsistent observations, with report of both pile-up and sink-in. This may be due to the crystallographic orientation of the measured sample point, which is often not considered when evaluating implantation-induced changes in the deformation response. Here we explore the orientation dependence of spherical nano-indentation in pure and helium-implanted tungsten, considering grains with , and out-of-plane orientations. Atomic force microscopy (AFM) of indents in unimplanted tungsten shows little orientation dependence. However, in the implanted material a much larger, more localised pile-up is observed for grains than for and orientations. Based on the observations for grains, we hypothesise that a large initial hardening due to helium-induced defects is followed by localised defect removal and subsequent strain softening. A crystal plasticity finite element model of the indentation process, formulated based on this hypothesis, accurately reproduces the experimentally-observed orientation-dependence of indent morphology. The results suggest that the mechanism governing the interaction of helium-induced defects with glide dislocations is orientation independent. Rather, differences in pile-up morphology are due to the relative orientations of the crystal slip systems, sample surface and spherical indenter. This highlights the importance of accounting for crystallographic orientation when probing the deformation behaviour of ion-implanted materials using nano-indentation.

Keywords: response; orientation; indentation; helium implanted; implanted tungsten

Journal Title: Applied Physics Letters
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.