OBJECTIVE We tested the hypothesis that a single-phase neck computed tomography (CT) is not inferior to multiphase neck CT (MPNCT), ultrasound, or nuclear medicine sestamibi scan in identifying parathyroid adenomas… Click to show full abstract
OBJECTIVE We tested the hypothesis that a single-phase neck computed tomography (CT) is not inferior to multiphase neck CT (MPNCT), ultrasound, or nuclear medicine sestamibi scan in identifying parathyroid adenomas (PAs). METHODS A total of 29 patients who had an MPNCT for the evaluation of a PA were identified; 11 patients met the inclusion criteria. During the 30-second arterial phase CT (APNCT), a normalized Hounsfield unit of suspected PA was compared to Hounsfield unit of a normal-appearing level I and a level II lymph node. A PA was defined as a lesion with a ratio of greater than 1.4 when compared to the level I and level II lymph node. This cutoff was determined based on the normalized ratios between level II and level I lymph nodes. Results of intraoperative parathyroid hormone assays and surgical pathology were used to validate the accuracy of this technique. RESULTS The sensitivity of this method in APNCT is 90.9% whereas positive predictive value is 100%. The sensitivity or positive predictive value of ultrasound and nuclear medicine are 60% or 100% and 90% or 100%, respectively. CONCLUSION The sensitivity of APNCT is equivalent to that of MPNCT in identifying PA.
               