ABSTRACT For basic information on new regulatory criteria, the dose rate around a thick target bombarded by proton, electron, or carbon beam having incident energy of 10 MeV–50 GeV (per… Click to show full abstract
ABSTRACT For basic information on new regulatory criteria, the dose rate around a thick target bombarded by proton, electron, or carbon beam having incident energy of 10 MeV–50 GeV (per nucleon in case of carbon) was simulated using the PHITS Monte Carlo code. Based on this simulation, the benchmark which is ‘1 Sv/h at 1 m away from the beam line’ assuming 1% beam loss was evaluated, and compared with the criteria in France and Canada. Based on this evaluation, a new regulatory criteria has been established for requiring on-site emergency preparedness for accelerator facilities in Japan, which is required for the ion accelerator beyond the ion beam of 100 MeV/nucleon and 0.5 kW beam power, and the electron accelerator beyond the electron beam of 50 MeV energy and 1 kW beam power.
               