LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Paclitaxel coated balloon versus conventional balloon angioplasty in dysfunctional dialysis arteriovenous fistula: a systematic review and meta-analysis of randomized controlled trials

Photo from wikipedia

Abstract Purpose To compare the efficacy and safety between paclitaxel coated balloon (PCB) angioplasty and conventional balloon (CB) angioplasty in the treatment of dysfunctional arteriovenous fistula (AVF). Methods We searched… Click to show full abstract

Abstract Purpose To compare the efficacy and safety between paclitaxel coated balloon (PCB) angioplasty and conventional balloon (CB) angioplasty in the treatment of dysfunctional arteriovenous fistula (AVF). Methods We searched four major electronic databases (PubMed, EMBASE, Web of Science and the Cochrane Library) for randomized controlled trials (RCTs) published from inception through November 28, 2021. Outcomes of interest included target lesion primary patency (TLPP), technical success and all-cause mortality. The STATA package version 15.1 was utilized to undertake meta-analyses. Results Fourteen RCTs totaling 1535 patients were analyzed. The available data showed that there were no significant differences of TLPP rates at 3, 6, 9 and 12 months between the PCB group and the CB group (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.93–1.07, p = 1.000, I 2 = 33.5%, Cochrane Q test p = 0.185, fixed-effect model; RR 1.17, 95% CI 0.99–1.39, p = 0.065, I 2 = 75.4%, Cochrane Q test p = 0.000, random-effect model; RR 0.81, 95% CI 0.35–1.89, p = 0.625, I 2 = 62.8%, Cochrane Q test p = 0.045, random-effect model; RR 1.19, 95% CI 0.97–1.47, p = 0.096, I 2 = 40.5%, Cochrane Q test p = 0.071, random-effect model). In addition, two groups had similar technical success rates (RR 1.00, 95% CI 0.97–1.03, p = 1.000, I 2 = 0.0%, Cochrane Q test p = 0.596, fixed-effect model) and all-cause mortality rates (RR 1.00, 95% CI 0.54–1.84, p = 1.000, I 2 = 0.0%, Cochrane Q test p = 0.599, fixed-effect model). Conclusions PCB angioplasty did not appear to convey any obvious advantage over CB angioplasty in the treatment of dysfunctional AVF. However, further multi-center, large-scale and well-designed RCTs are needed to prove outcomes.

Keywords: cochrane test; balloon; effect model

Journal Title: Renal Failure
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.