LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

First-in-human study to assess the pharmacokinetics, tolerability, and safety of single-dose oxybutynin hydrochloride administered via a microprocessor-controlled intravaginal ring

Photo from wikipedia

Abstract Polymeric drug-releasing vaginal rings are useful for both local and systemic administration of drugs via the intravaginal route. Typically, they provide continuous sustained or controlled release of drug(s) over… Click to show full abstract

Abstract Polymeric drug-releasing vaginal rings are useful for both local and systemic administration of drugs via the intravaginal route. Typically, they provide continuous sustained or controlled release of drug(s) over extended time periods, thereby avoiding overdose and improving adherence. This first-in-human study (EudraCT number: 2020-0050044-30) evaluated the pharmacokinetics, safety, and tolerability of a single dose of oxybutynin administered by a novel microprocessor-controlled vaginal ring (MedRing). Eight healthy female subjects received an electronically controlled single intravaginal dose of 3 mg oxybutynin hydrochloride (100 mg/mL) dissolved in 1:1 water/propylene glycol administered via MedRing. Following dosing, MedRing was kept in situ for up to 6 h. Blood samples were collected 1 h prior to oxybutynin dosing and subsequently at regular intervals post-dose for the assessment of plasma concentrations of oxybutynin and its active metabolite N-desethyloxybutynin. The results showed that MedRing efficiently administered oxybutynin via the intravaginal route, resulting in plasma oxybutynin levels comparable to orally administered oxybutynin. The mean ± standard deviation pharmacokinetic parameters for oxybutynin were Cmax 5.4 ± 2.7 ng/mL, AUCinf 34.9 ± 17.4 h ng/mL, t1/2 8.5 ± 3.5 h and for N-desethyloxybutynin were Cmax 3.9 ± 2.5 ng/mL, AUCinf 51.1 ± 43.1 h ng/mL, t1/2 7.7 ± 5.9 h. No serious adverse events were reported. The study demonstrates that intravaginal administration of oxybutynin hydrochloride using the MedRing device was well tolerated.

Keywords: oxybutynin; oxybutynin hydrochloride; human study; dose oxybutynin; first human

Journal Title: Drug Delivery
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.