ABSTRACT Seismic performance assessment is carried out for reinforced concrete structure built in low-strength concrete lacking confining ties in beam-column joint. Shake-table tests were performed on 1/3rd scaled two-story frame… Click to show full abstract
ABSTRACT Seismic performance assessment is carried out for reinforced concrete structure built in low-strength concrete lacking confining ties in beam-column joint. Shake-table tests were performed on 1/3rd scaled two-story frame using design-spectrum-compatible accelerogram, scaled to various target levels. The frame is observed with beam longitudinal bar slip and pullout. Joints with no confining ties experienced extensive damage, observed with cover/core concrete spalling. The frame could resist 70% of the design ground motion to remain within the code-specified drift limit. The code requirement for minimum column depth will not avoid joint damageability in case of low-strength concrete and joints lacking confining ties.
               