LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Effectiveness and safety of implantable loop recorder and clinical utility of remote monitoring in patients with unexplained, recurrent, traumatic syncope

Photo by jentheodore from unsplash

ABSTRACT Background Implantable loop recorder (ILR) is still underutilized in clinical practice, especially in the setting of elderly patients with recurrent, traumatic, unexplained syncope. Data on the actual risk of… Click to show full abstract

ABSTRACT Background Implantable loop recorder (ILR) is still underutilized in clinical practice, especially in the setting of elderly patients with recurrent, traumatic, unexplained syncope. Data on the actual risk of traumatic syncopal recurrence during ILR monitoring in this specific patient setting are lacking. Research design and methods Prospective, multicentre registry enrolling consecutive patients undergoing ILR insertion for unexplained, recurrent, traumatic syncope. In a proportion of enrolled patients, remote monitoring (RM) was used for device follow-up. The risk of traumatic and non-traumatic syncopal recurrences during ILR observation were prospectively assessed. Results A total of 483 consecutive patients (68±14 years, 59% male) were enrolled. During a median follow-up of 18 months, a final diagnosis was reached in 270 patients (55.9%). The risk of syncopal and traumatic syncopal recurrence was of 26.5 and 9.3%, respectively. RM significantly reduced the time to diagnosis (19.7±10.3 vs. 22.1±10.8 months; p=0.015) and was associated with a significant reduction in the risk of syncope recurrence of 48% (p<0.001), and of traumatic syncope recurrence of 49% (p=0.018). Conclusions ILR monitoring is effective and safe in patients with unexplained, recurrent, traumatic syncope. RM reduces the time to diagnosis and significantly reduces the risk of traumatic and non-traumatic syncopal relapses.

Keywords: syncope; unexplained recurrent; recurrent traumatic; implantable loop; risk; traumatic syncope

Journal Title: Expert Review of Medical Devices
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.