Water equivalent path length calculations using scatter-corrected head and neck CBCT images to evaluate patients for adaptive proton therapy.

Photo by anniespratt from unsplash

Proton therapy has dosimetric advantages due to the well-defined range of the proton beam over photon radiotherapy. When the proton beams, however, are delivered to the patient in fractionated radiation… Click to show full abstract

Proton therapy has dosimetric advantages due to the well-defined range of the proton beam over photon radiotherapy. When the proton beams, however, are delivered to the patient in fractionated radiation treatment, the treatment outcome is affected by delivery uncertainties such as anatomic change in the patient and daily patient setup error. This study aims at establishing a method to evaluate the dosimetric impact of the anatomic change and patient setup error during head and neck proton therapy. Range variations due to the delivery uncertainties were assessed by calculating water equivalent path length (WEPL) to the distal edge of tumor volume using planning CT and weekly treatment cone-beam CT (CBCT) images. Specifically, mean difference and root mean squared deviation (RMSD) of the distal WEPLs were calculated as the weekly range variations. To accurately calculate the distal WEPLs, an existing CBCT scatter correction algorithm was used. An automatic rigid registration was used to align the planning CT and treatment CBCT images, simulating a six degree-of-freedom couch correction at treatments. The authors conclude that the dosimetric impact of the anatomic change and patient setup error was reasonably captured in the differences of the distal WEPL variation with a range calculation uncertainty of 2%. The proposed method to calculate the distal WEPL using the scatter-corrected CBCT images can be an essential tool to decide the necessity of re-planning in adaptive proton therapy.

Keywords: cbct images; proton; cbct; proton therapy; scatter

Journal Title: Physics in medicine and biology
Year Published: 2017

Link to full text (if available)