LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Optimization of the reconstruction parameters in [123I]FP-CIT SPECT.

Photo from wikipedia

The aim of this work was to obtain a set of parameters to be applied in [123I]FP-CIT SPECT reconstruction in order to minimize the error between standardized and true values… Click to show full abstract

The aim of this work was to obtain a set of parameters to be applied in [123I]FP-CIT SPECT reconstruction in order to minimize the error between standardized and true values of the specific uptake ratio (SUR) in dopaminergic neurotransmission SPECT studies. To this end, Monte Carlo simulation was used to generate a database of 1380 projection data-sets from 23 subjects, including normal cases and a variety of pathologies. Studies were reconstructed using filtered back projection (FBP) with attenuation correction and ordered subset expectation maximization (OSEM) with correction for different degradations (attenuation, scatter and PSF). Reconstruction parameters to be optimized were the cut-off frequency of a 2D Butterworth pre-filter in FBP, and the number of iterations and the full width at Half maximum of a 3D Gaussian post-filter in OSEM. Reconstructed images were quantified using regions of interest (ROIs) derived from Magnetic Resonance scans and from the Automated Anatomical Labeling map. Results were standardized by applying a simple linear regression line obtained from the entire patient dataset. Our findings show that we can obtain a set of optimal parameters for each reconstruction strategy. The accuracy of the standardized SUR increases when the reconstruction method includes more corrections. The use of generic ROIs instead of subject-specific ROIs adds significant inaccuracies. Thus, after reconstruction with OSEM and correction for all degradations, subject-specific ROIs led to errors between standardized and true SUR values in the range [-0.5, +0.5] in 87% and 92% of the cases for caudate and putamen, respectively. These percentages dropped to 75% and 88% when the generic ROIs were used.

Keywords: reconstruction; optimization reconstruction; reconstruction parameters; 123i cit; cit spect; rois

Journal Title: Physics in medicine and biology
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.