Verification of the machine delivery parameters of treatment plan via deep learning.

Photo from wikipedia

We developed a generative adversarial network (GAN)-based deep learning approach to estimate the multileaf collimator (MLC) aperture and corresponding monitor units (MUs) from a given three dimensional (3D) dose distribution.… Click to show full abstract

We developed a generative adversarial network (GAN)-based deep learning approach to estimate the multileaf collimator (MLC) aperture and corresponding monitor units (MUs) from a given three dimensional (3D) dose distribution. The proposed design of adversari-al network, which integrates a residual block into pix2pix framework, jointly trains a "U-Net"-like architecture as generator and a convolutional "PatchGAN" classifier as dis-criminator. 199 patients, including nasopharyngeal, lung and rectum, treated with intensi-ty modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) tech-niques were utilized to train the network. Additional 47 patients were used to test the prediction accuracy of the proposed deep learning model. The Dice similarity coefficient (DSC) was calculated to evaluate the similarity between the MLC aperture shapes ob-tained from the treatment planning system (TPS) and the deep learning prediction. The average and standard deviation of the bias between the TPS generated MUs and predicted MUs were calculated to evaluate the MU prediction accuracy. Additionally, the differences between TPS and deep learning-predicted MLC leaf positions were compared. The average and standard deviation of DSC was 0.94 ± 0.043 for 47 testing patients. The average deviation of predicted MUs from the planned MUs normalized to each beam or arc was within 2% for all the testing patients. The average deviation of the predicted MLC leaf positions was around one pixel for all the testing patients. Our results demonstrated the feasibility and reliability of the proposed approach. The proposed technique has strong potential to improve the efficiency and accuracy of patient plan quality assurance (QA) process.

Keywords: deviation; testing patients; learning; treatment; deep learning; plan

Journal Title: Physics in medicine and biology
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.