LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

DIR-based models to predict weekly anatomical changes in head and neck cancer proton therapy.

Photo by thinkmagically from unsplash

PURPOSE We proposed two anatomical models for head and neck patients to predict anatomical changes during the course of radiotherapy. METHODS Deformable Image Registration was used to build two anatomical… Click to show full abstract

PURPOSE We proposed two anatomical models for head and neck patients to predict anatomical changes during the course of radiotherapy. METHODS Deformable Image Registration was used to build two anatomical models: 1) The average model (AM) simulated systematic progression changes across the patient cohort; 2) The refined individual model (RIM) used a patient's CT images acquired during treatment to update the prediction for each individual patient. Planning CTs and weekly CTs were used from 20 nasopharynx patients. This dataset included 15 training patients and 5 test patients. For each test patient, a spot scanning proton plan was created. Models were evaluated using CT number difference, contours, proton spot location deviation and gamma index. RESULTS If no model was used, the CT number difference between the planning CT and the repeat CT at week 6 of treatment was on average 128.9 HU over the test population. This can be reduced to 115.5 HU using the AM, and to 110.5 HU using the RIM3(RIM, updated at week 3). When the predicted contours from the models were used, the average mean surface distance of parotid glands can be reduced from 1.98 mm (no model) to 1.16 mm (AM) and 1.19 mm (RIM3) at week 6. Using proton spot range, the average anatomical uncertainty over the test population reduced from 4.47±1.23 mm (no model) to 2.41±1.12 mm (AM), and 1.89±0.96 mm (RIM3). Based on the gamma analysis, the average gamma index over the test patients was improved from 93.87±2.48 % (no model) to 96.16±1.84 % (RIM3) at week 6. CONCLUSIONS The AM and the RIM both demonstrated the ability to predict anatomical changes during the treatment. The RIM can gradually refine the prediction of anatomical changes based on the AM. The proton beam spots provided an accurate and effective way for uncertainty evaluation.

Keywords: head neck; anatomical changes; model rim3; proton; week

Journal Title: Physics in medicine and biology
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.