LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Accuracy enhancement in reflective pulse oximetry by considering wavelength-dependent pathlengths

Photo by benceboros from unsplash

Objective. Noninvasive measurement of oxygen saturation (SpO 2) using transmissive photoplethysmography (tPPG) is clinically accepted and widely employed. However, reflective photoplethysmography (rPPG)—currently present in smartwatches—has not become equally accepted, partially… Click to show full abstract

Objective. Noninvasive measurement of oxygen saturation (SpO 2) using transmissive photoplethysmography (tPPG) is clinically accepted and widely employed. However, reflective photoplethysmography (rPPG)—currently present in smartwatches—has not become equally accepted, partially because the pathlengths of the red and infrared PPGs are patient-dependent. Thus, even the most popular ‘Ratio of Modulation’ (R) method requires patient-dependent calibration to reduce the errors in the measurement of SpO 2 using rPPGs. Approach. In this paper, a correction factor or ‘pathlength ratio’ β is introduced in an existing calibration-free algorithm that compensates the patient-dependent pathlength variations, and improved accuracy is obtained in the measurement of SpO 2 using rPPGs. The proposed pathlength ratio β is derived through the analytical model of a rPPG signal. Using the new expression and data obtained from a human hypoxia study wherein arterial oxygen saturation values acquired through Blood Gas Analysis were employed as a reference, β is determined. Main results. The results of the analysis show that a specific combination of the β and the measurements on the pulsating part of the natural logarithm of the red and infrared PPG signals yields a reduced root-mean-square error (RMSE). It is shown that the average RMSE in measuring SpO 2 values reduces to 1 %. Significance. The human hypoxia study data used for this work, obtained in a previous study, covers SpO 2 values in the range from 70 % to 100 %, and thus shows that the pathlength ratio β proposed here works well in the range of clinical interest. This work demonstrates that the calibration-free method applicable for transmission type PPGs can be extended to determine SpO 2 using reflective PPGs with the incorporation of the correction factor β. Our algorithm significantly reduces the number of parameters needed for the estimation, while keeping the RMSE below the clinically accepted 2 %.

Keywords: spo using; pathlength ratio; accuracy enhancement; spo; patient dependent

Journal Title: Physiological Measurement
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.