To carry out the charge exchange reaction experiments in inverse kinematics, a Time Projection Chamber (TPC) based on the Thick Gas Electron Multiplier was constructed. This paper focuses on evaluating… Click to show full abstract
To carry out the charge exchange reaction experiments in inverse kinematics, a Time Projection Chamber (TPC) based on the Thick Gas Electron Multiplier was constructed. This paper focuses on evaluating its position and energy measurement capabilities with the α radiation sources. For position resolution, the dependencies on drift distance and scattering angle were investigated. In the x-direction, position resolution was consistently better than 400 μm across various drift distances. In the z-direction, it remained better than 300 μm for different drift distances and scattering angles. For energy measurement, the resolution for ∼5 MeV α particles was approximately 8% (FWHM) and the good linearity in energy response was exhibited. The tests demonstrated that the TPC's performance in measuring the position and energy of charged particles like α particles is adequate to satisfy the requirements for future experiments aimed at the extraction of track information and energy deposition.
               