LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Homogeneous time-resolved fluoroimmunoassay of microcystin-LR using layered WS2 nanosheets as a transducer.

Photo by jontyson from unsplash

A homogeneous time-resolved fluoroimmunoassay method for rapid and sensitive detection of microcystin-LR (MC-LR) in water samples was developed based on the interaction between water-soluble WS2 nanosheets and the conjugate of… Click to show full abstract

A homogeneous time-resolved fluoroimmunoassay method for rapid and sensitive detection of microcystin-LR (MC-LR) in water samples was developed based on the interaction between water-soluble WS2 nanosheets and the conjugate of MC-LR with a luminescent Eu3+ complex BHHBCB-Eu3+ (BHHBCB: 1,2-bis[4'-(1″,1″,1″,2″,2″,3″,3″-heptafluoro-4″,6″-hexanedion-6″-yl)- benzyl]-4-chlorosulfobenzene). The large lateral dimensions and high surface areas of two-dimensional layered WS2 nanosheets enable easy adsorption of the MC-LR-BHHBCB-Eu3+ conjugate, that lead to efficient quenching of the luminescence of Eu3+ complex via energy transfer or electron transfer process. However, the addition of monoclonal anti-MC-LR antibody can induce the formation of MC-LR-BHHBCB-Eu3+/antibody immune complex, which prevents the interaction between WS2 nanosheets and MC-LR-BHHBCB-Eu3+ to result in the restoration of Eu3+ luminescence. This signal transduction mechanism made it possible for analysis of the target MC-LR in a homogeneous system. The present method has advantages of rapidity and simplicity since the B/F (bound reagent/free reagent) separation steps, the solid-phase carrier and antibody labeling or modification process are not necessary. The proposed immunosensing system displayed a wide linear range, good precision and accuracy, and comparable sensitivity with a detection limit of 0.3 μg l-1, which satisfied the World Health Organization (WHO) provisional guideline limit of 1.0 μg l-1 for MC-LR in drinking water.

Keywords: resolved fluoroimmunoassay; homogeneous time; eu3; time resolved; bhhbcb eu3; ws2 nanosheets

Journal Title: Methods and applications in fluorescence
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.