LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Electrocoagulation accounts for a significant portion of discrepancy between preoperative ultrasonography prostate size estimation and resected tissue weight.

Photo from wikipedia

BACKGROUND AND OBJECTIVES Transurethral resection of the prostate (TURP) is considered to be the gold standard surgical procedure for medium-sized prostates. However, there is a drastic difference between the weight… Click to show full abstract

BACKGROUND AND OBJECTIVES Transurethral resection of the prostate (TURP) is considered to be the gold standard surgical procedure for medium-sized prostates. However, there is a drastic difference between the weight of resected tissue reported by the pathologist and the sonographic estimate of prostate weight before the operation. The present study investigates the role of electrocoagulation in tissue loss during monopolar (M-) and bipolar (B-) TURP. METHODS In this experimental in vitro study, 33 prostate glands removed from patients by open suprapubic prostatectomy were roughly divided in half and the weight of each half was recorded precisely. One half of the specimen was resected using a monopolar resectoscope and the other half was resected by bipolar resectoscope in an out-of-body simulated condition. The weight of obtained chips was measured and the amount of lost tissue was calculated. Data from prostates with final pathologic diagnosis of benign prostatic hyperplasia (BPH) was included in the analysis. The mean difference of prostate weight before and after out-of-body resection and also the proportion of tissue loss between M-TURP and B-TURP were compared using t-test. RESULTS Data from 62 prostate halves were included in the final analysis. The mean weight of samples after M-TURP was considerably lower than before resection (38.0±6.9 and 48.7±9.0 respectively, p<0.001). Similarly, the mean weight of prostate samples after B-TURP was lower than the weight before resection (36.2±7.3 and 48.4±9.1 respectively, p<0.001). However, the ratio of tissue loss in B-TURP (25.3%±2.5%) was significantly lower than in M-TURP (21.3%±3.7%) (p<0.001). CONCLUSION Prostate resection using electrocoagulation leads to a significant prostate tissue loss due to heat effect. Furthermore, tissue loss in B-TURP is slightly more than M-TURP.

Keywords: prostate; weight; turp; tissue loss; resection

Journal Title: Journal of endourology
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.