The Usefulness of a Three-Microneedle Device for Indocyanine Green Fluorescence Lymphography.

Photo by hakannural from unsplash

Background: Indocyanine green (ICG) fluorescence lymphography is widely used to diagnose lymphedema. There is little consensus on the appropriate injection method for ICG fluorescence lymphangiography. We used a three-microneedle device… Click to show full abstract

Background: Indocyanine green (ICG) fluorescence lymphography is widely used to diagnose lymphedema. There is little consensus on the appropriate injection method for ICG fluorescence lymphangiography. We used a three-microneedle device (TMD) for skin injection of ICG solution and investigated its usefulness. Methods and Results: Thirty healthy volunteers were injected with ICG solution using a 27-gauge (27G) needle in one foot and a TMD in the other foot. Injection-related pain was evaluated using the Numerical Rating Scale (NRS) and Face Rating Scale (FRS). The skin depth of the injected ICG solution was evaluated by injecting the solution into the skin of amputated lower limbs using a 27G needle or TMD using ICG fluorescence microscopy. The median and interquartile range of the NRS scores was 3 (3-4) and 2 (2-4) in the 27G needle and TMD groups, respectively; that of the FRS scores was 2 (2-3) and 2 (1-2) in the 27G needle and TMD groups, respectively. Injection-related pain was significantly lower with the TMD than with the 27G needle. The lymphatic vessels were similarly visible using both needles. The depth of the ICG solution varied for each injection with a 27G needle (400-1200 μm) and was consistent at ∼300-700 μm below the skin surface using the TMD. Injection depth was significantly different between the 27G needle and the TMD. Conclusions: Injection-related pain decreased using the TMD, and ICG solution depth was consistent on fluorescence lymphography. A TMD may be useful for ICG fluorescence lymphography. Clinical Trials Registry (UMIN-CTR; ID: UMIN000033425).

Keywords: injection; tmd; fluorescence lymphography; 27g needle; fluorescence

Journal Title: Lymphatic research and biology
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.