LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Development and Validation of Chemometrics-Assisted Green UPLC-MS/MS Bioanalytical Method for Simultaneous Estimation of Capecitabine and Lapatinib in Rat Plasma.

Photo from wikipedia

A chemometrics-oriented green ultra-performance liquid chromatography-mass spectrometry/mass spectrometry method was developed and validated for the first-time simultaneous estimation of capecitabine (CAP) and lapatinib (LPB) along with imatinib (as internal standard… Click to show full abstract

A chemometrics-oriented green ultra-performance liquid chromatography-mass spectrometry/mass spectrometry method was developed and validated for the first-time simultaneous estimation of capecitabine (CAP) and lapatinib (LPB) along with imatinib (as internal standard (IS)) in rat plasma. Analytes were extracted using ethyl acetate as the liquid-liquid extraction media. In the pre-development phase, principles of analytical eco-scale were used to confirm method greenness. Subsequently, vital method variables, influencing method robustness and performance, were optimized using a chemometrics-based quality-by-design approach. Chromatography was achieved on a BEH C18 (100 × 2.1 mm, 1.7 μm) using isocratic flow (0.5 mL.min-1) of mobile phase acetonitrile (0.1% formic acid):0.002 M ammonium acetate in water as the mobile phase. The mass spectrometric detections were carried out in multiple reaction monitoring modes with precursor-to-product ion transitions with m/z 360.037 → 244.076 for CAP, m/z 581.431 → 365.047 LPB and m/z 494.526 → 394.141 for IS. The bioanalytical method validation studies were performed, ensuring regulatory compliance. Linearity (r2> 0.99) over analyte concentrations ranging from 5 and 40 ng.mL-1 was observed, while acceptable values were obtained for all other validation parameters. In a nutshell, a robust and green bioanalytical method was developed and applied for the simultaneous estimation of two anticancer agents from rat plasma.

Keywords: rat plasma; validation; simultaneous estimation; method; bioanalytical method

Journal Title: Journal of chromatographic science
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.