285Arrhythmias after transcatheter closure of persistent foramen ovale are related to the type and size of the implanted device

Photo from wikipedia

Transient supraventricular arrhythmias may occur in patients following persistent foramen ovale (PFO) closure. Therefore, the aim of the study was to prospectively perform 24-hour ECG monitoring to assess the electrocardiographic… Click to show full abstract

Transient supraventricular arrhythmias may occur in patients following persistent foramen ovale (PFO) closure. Therefore, the aim of the study was to prospectively perform 24-hour ECG monitoring to assess the electrocardiographic effects of transcatheter closure of PFO depending on the type of implanted devices. 351 consecutive adult subjects (196 F, 155M; mean age: 40.9±15.3) were enrolled into the study to undergo PFO closure with an Amplatzer Septal Occluder - ASO (157 pts: 117 occluders – size 25; 40 pts – size 30), and Cardia device (194 pts: 163 occluders – size 25; 31 – size 30). Holter monitoring was performed on all patients before, at 1 and 12 months after the procedure. The success rate of PFO closure was 97.8% (351 cases from 359 qualified in TEE), in 8 cases the PFO tunnels were too small to be forced by a catheter, in one case the PFO device caused an injury of the septum and an ASD Amplatzer device was implanted. During the procedure in 3 (0.85%) cases transient supraventricular arrhythmia and in 1 (0.28%) case bradycardia to 27 bpm occurred. At 1 month: in 7 (2%) pts changes in AV conduction occurred: 1 pt (0.28%) had complete AV dissociation, 6 (1.7%) pts intermittent first degree AV block; paroxysmal atrial fibrillation (pAF) occurred in 6 (1.7%) pts, 2 of whom had pAF prior to closure. A significant increase in the number of SVE premature beats/24h was noted at 1 month after the procedure: 1167.9±409 (27–9976) compared to baseline data 60.2±44 (0–601) (p<0.0001), at 12 months the SVE number decreased to 57.2±51 (7–752) and did not differ significantly from the baseline data. There was no change in the mean number of ventricular arrhythmias/24h after the procedure. There was a significant correlation between SVE premature beats/24h at 1 month after the procedure and device size (p<0.001 r=97211). Pts with ASO device had a significantly higher number of SVE ectopy at 1 month after PFO closure (19123.9±70) compared to pts with Cardia device (811.9±324), p<0.0001. 1. Transcatheter closure of PFO is associated with a transient increase in supraventricular premature beats and a small risk of AV conduction abnormalities and paroxysmal atrial fibrillation in the early follow-up. There is regression of periprocedural arrhythmias after 12 months of PFO closure. 2. Transcatheter closure of PFO with Cardia device is related to a lower risk of supraventricular arrhythmias in the early follow-up. 3. The smaller device is implanted the lower risk of periprocedural arrhythmias is expected.

Keywords: device; transcatheter closure; closure; pfo closure; size

Journal Title: European Heart Journal
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.