LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

P2804Initial experience with the novel BioMime Morph 40–60 mm long sirolimus-eluting tapered stent in long coronary lesions

Photo by andreacaramello from unsplash

Aims: Long lesions treated with overlapping stents has been reported to be associated with healing problems and/or adverse events. The novel BioMime Morph is a 40, 50 and 60 mm… Click to show full abstract

Aims: Long lesions treated with overlapping stents has been reported to be associated with healing problems and/or adverse events. The novel BioMime Morph is a 40, 50 and 60 mm long sirolimus-eluting cobalt chromium stent (65 μm strut thickness, biodegradable polymer) with a tapered design (0.5 mm taper from proximal to distal end) and is available in the following proximal and distal diameters (2.75–2.2 5mm, 3–2.5 mm and 3.5–3 mm). It can be a novel alternative for treatment of long coronary lesions, overcoming the limitations of overlapping stents. Methods: Data was evaluated from our centre's prospective BioMime Morph database from August 2016 - January 2019. Primary endpoint was device oriented composite endpoint (DOCE: cardiac death, TV-MI, TLR and TVR). Secondary endpoints were technical (successful Morph implantation) and procedural success (successful procedure with Morph without in-hospital MACE). 103 patients had BioMime Morph stents implanted, with mean follow up of 411 (±214) days and a mean age of 66 (±11) years. Co-morbidities included hypertension (58%), hypercholesterolemia (38%), diabetes mellitus (28%), PVD (2%), CVD (5%), CKD (12%), previous MI (17%), smoking (40%) and positive family history (20%). There was history of previous PCI in 18% and CABG in 4%. Indication for PCI was predominantly ACS (78% including 13% STEMI), 15% were CTOs. 80% of the procedures were performed via radial access using 5–6F sheath in 73%. Vessels treated included LAD (43%), Cx (12%) and RCA (45%). Pre-dilatation was performed in 96% including use of non-complaint balloons in 51%, scoring balloons in 12% and rotablation in 4%. Post-dilatation was performed in 99%. Buddy wire was used in 41% while a guideliner used in 13%. Technical success (secondary endpoint) was achieved in 100 whilst procedural success was achieved in 96% (4 cases of contrast induced nephropathy). Cumulative DOCE (primary endpoint) was % (cardiac death 1%, TV-MI 1%, definitive ST 0%, possible ST 1%, TLR 2% and TVR 2%). OCT follow up at 1 month, 3 month and 6 months in 2 patients showed endothelialisation even at 1 month. Our initial experience of the use of the novel BioMime Morph tapered DES for treatment of long coronary lesions exhibit promising results in short to medium follow-up. Elution of the drug in 1 month along with biodegradable polymer and ultra thin struts potentially helps early healing and raises the possibility of short DAPT even in these complex long lesions. BioMime Morph stents can potentially be an alternative to overlapping conventional stents for treating long coronary lesions.

Keywords: coronary lesions; novel biomime; morph; long coronary; biomime morph

Journal Title: European Heart Journal
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.