LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

ECG wearable rhythm monitoring in covid-19 patients

Photo from wikipedia

Abstract Funding Acknowledgements Type of funding sources: None. Background Wearable monitors and external smart-phone enabled devices represent the new era in remote patient management during covid-19 pandemy. There is growing… Click to show full abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background Wearable monitors and external smart-phone enabled devices represent the new era in remote patient management during covid-19 pandemy. There is growing evidence showing that arrhythmias are one of the major complications of SARS-CoV-2 infection especially in high risk group of patients. Methods We enrolled 34consecutive patients with confirmed diagnosis of SARS-CoV-2 (mean age62.45 ± 5.25years, 16male). Remote wireless rhythm monitoring was performed using portative ECG sensor.Average follow-up period was 21 days during in-hospital stage and 2 months after discharge. Results Among hospitalized patients with verified SARS-CoV-2 some presented different arrhytmias before admission (9 patients had atrial fibrillation and 11 patients had history of ventricular extrasystoles and non-sustained ventricular tachycardia). One patient underwent cardiac transplantation 1.5 years ago (female 38 years old with a history of dilated cardiomyopathy) and one patient had implanted CRTD device as primary prevention (male 54 years old with a history of myocardial infarction and low LVEF 28%). Other 12 patients did not experience any cardiac arrhythmias before admission. During monitoring period one patient demonstrated asymptomatic pauses longer than 6 seconds (Figure 1) revealed by portative device. After 2 months of follow up he continued to have hemodinamycally significant rhythm pauses and underwent pacemaker implantation. One patient had spontaneus AF conversion into sinus rhythm (Figure 2) also confirmed by wireless monitoring. Other patients did not demonstrate clinically significant arrhythmias. The duration of QT interval was also monitored during in-hospital period in all patients, average score was 451 ± 12 msec. Conclusions Using of wearable electronic devices may contribute to better monitoring of the state of patients and control of symptoms. Abstract Figure. Hemodynamically significant rhythm pause

Keywords: rhythm; one patient; rhythm monitoring; covid; monitoring

Journal Title: Europace
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.