LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Novel dual-reference approach facilitates the activation mapping and catheter ablation of premature atrial complexes with non-pulmonary vein and non-superior vena cava origins

Photo from wikipedia

Abstract Aims Activation mapping of premature atrial complexes (PACs) proves challenging due to interference by mechanical bumping and non-targeted ectopies. This study aims to compare the mapping efficacy, instant success,… Click to show full abstract

Abstract Aims Activation mapping of premature atrial complexes (PACs) proves challenging due to interference by mechanical bumping and non-targeted ectopies. This study aims to compare the mapping efficacy, instant success, and long-term recurrence of catheter ablation for PACs with non-pulmonary vein (PV) and non-superior vena cava (SVC) origins between the novel dual-reference approach (DRA) and the routine single-reference approach (SRA) of mapping. Methods and results Patients with symptomatic, drug-refractory PACs, or frequent residual PACs after atrial tachyarrhythmia ablation were enrolled. During activation mapping, the coronary sinus (CS) catheter was used as the only timing reference in the SRA group. In the DRA group, another catheter, which was spatially separated from the CS catheter, was used as the second reference. The timing difference between the two references was used to discriminate the targeted PACs from the uninterested rhythms. Procedural parameters and long-term recurrence were compared. A total of 188 patients (109 in SRA and 79 in DRA) were enrolled. The baseline characteristics were similar. Compared with the SRA group, the DRA group had less repeated mapping (1.2 ± 0.4 vs. 1.4 ± 0.5, P = 0.004), shorter mapping (15 ± 6 vs. 23 ± 7 min, P < 0.001) and procedural time (119 ± 28 vs. 132 ± 22 min, P = 0.001), similar procedural complication rates (3.6 vs. 3.8%, P > 0.999), higher instant success (96.2 vs. 87.2%, P = 0.039), and lower recurrence rate (15.2 vs. 29.3%, hazard ratio 1.943, P = 0.033) during a 24-month follow-up. Conclusion As a novel strategy, the DRA shortens the procedural time and improves both instant and long-term success of PAC ablation, serving as a promising approach in mapping PACs with non-PV and non-SVC origins.

Keywords: catheter; reference; ablation; reference approach; activation mapping

Journal Title: Europace
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.