LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre

Photo by ldxcreative from unsplash

Abstract Aims To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs.… Click to show full abstract

Abstract Aims To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. Methods and results Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. Conclusion The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.

Keywords: extraction; group; dwell time; time years; icd leads

Journal Title: Europace
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.