LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Surface acoustic wave (SAW) real-time interaction analysis of influenza A virus hemagglutinins with sialylated neoglycolipids.

Photo from wikipedia

Real-time interaction analysis of H1 hemagglutinin from influenza A H1N1 (A/New York/18/2009) and H7 hemagglutinin from influenza A H7N7 (A/Netherlands/219/03) with sialylated neoglycolipids (neoGLs) was performed using the surface acoustic… Click to show full abstract

Real-time interaction analysis of H1 hemagglutinin from influenza A H1N1 (A/New York/18/2009) and H7 hemagglutinin from influenza A H7N7 (A/Netherlands/219/03) with sialylated neoglycolipids (neoGLs) was performed using the surface acoustic wave (SAW) technology. The produced neoGLs carried phosphatidylethanolamine (PE) as lipid anchor and terminally sialylated lactose (Lc2, Galβ1-4Glc) or neolactotetraose (nLc4, Galβ1-4GlcNAcβ1-3Galβ1-4Glc) harbouring an N-acetylneuraminic acid (Neu5Ac). Using α2-6-sialylated neoGLs, H1 and H7 exhibited marginal attachment towards II6Neu5Ac-Lc2-PE, whereas Sambucus nigra lectin (SNL) exhibited strong binding and Maackia amurensis lectin (MAL) was negative in accordance with their known binding preference towards a distal Neu5Acα2-6Gal- and Neu5Acα2-3Gal-residue, respectively. H1 revealed significant binding towards IV6Neu5Ac-nLc4-PE when compared to weak interaction of H7, while SNL showed strong and MAL no attachment corresponding to their interaction specificities. Additional controls of MAL and SNL with α2-3-sialylated II3Neu5Ac-Lc2-PE and IV3Neu5Ac-nLc4-PE underscored the reliability of the SAW technology. Pre-exposure of model membranes spiked with α2-6-sialylated neoGLs to Vibrio cholerae neuraminidase substantially reduced the binding of the hemagglutinins and the SNL reference. Collectively, the SAW technology is capable of accurate measuring binding features of hemagglutinins towards neoGL-spiked lipid bilayers, which can be easily loaded to the functionalized biosensor gold surface thereby simulating biological membranes and suggesting promising clinical application for influenza virus research.

Keywords: real time; time interaction; surface; influenza; interaction analysis; interaction

Journal Title: Glycobiology
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.