Time-dependent mechanical behaviour of the aortic chronic dissection flap

Photo by jontyson from unsplash

Abstract OBJECTIVES The transition of aortic dissection from acute to chronic is poorly understood. We examined time-dependent mechanical behaviour and biochemical properties of chronic dissection tissues. METHODS Aorta samples were… Click to show full abstract

Abstract OBJECTIVES The transition of aortic dissection from acute to chronic is poorly understood. We examined time-dependent mechanical behaviour and biochemical properties of chronic dissection tissues. METHODS Aorta samples were obtained from 14 patients with mixed aetiology who were undergoing elective surgery for chronic dissected aneurysms, ranging from 3 months to 15 years post-dissection. The tissue elastic modulus and tissue deformation following application of loading for 5 h were measured for the false lumen (FL), true lumen (TL) and flap (FP) tissues with a custom-indentation technique. Collagen, elastin and glycosaminoglycan levels were determined with established biochemical assays. Elastin fragmentation was graded from histological sections. The number of tissues characterized was as follows: FP (n = 10), TL (n = 5 for biomechanical testing, n = 8 for biochemical analysis, n = 8 for histological assessment) and FL (n = 4). RESULTS Tissues stiffness was highest in FP [59.8 (14.8) kPa] as compared with TL [50.7 (6.2) kPa] and FL [40.5 (4.7) kPa] (P = 0.023 and P = 0.006, respectively). FP [0.5 (0.08) mm] also exhibited reduced deformation relative to TL [0.7 (0.02) mm] and FL [0.9 (0.08) mm] (P = 0.003 and P = 0.006, respectively), lowest collagen concentration [FP: 40.1 (19.6) µg/mg, TL: 59.9 (19.5) µg/mg, P = 0.008; FL: 79.1 (32.0) µg/mg, P = 0.006] and the lowest collagen: elastin ratio [0.4 (0.1)] relative to the other tissues [TL; 0.6 (0.3), P = 0.006, FL; 1.5 (0.4); P = 0.003]. Significant elastin loss was evident in the FL-stained tissue sections whereas highly aligned, long fibres were visible in the FP and TL. A linear relationship was found between the stiffness, deformation and the time from the dissection event to surgical intervention for the FP. All data are presented as median (interquartile range). CONCLUSIONS FP exhibited reduced time-dependent deformation and distinct biochemical properties relative to TL and FL irrespective of connective tissue disorder or the anatomical region of the dissection.

Keywords: time; time dependent; dependent mechanical; chronic dissection; dissection; mechanical behaviour

Journal Title: Interactive Cardiovascular and Thoracic Surgery
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.