LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Blood flow competition after aortic valve bypass: an evaluation using computational fluid dynamics.

Photo by matthardy from unsplash

OBJECTIVES Aortic valve bypass (AVB) (apico-aortic conduit) remains an effective surgical alternative for patients in whom surgical aortic valve replacement or transcatheter aortic valve implantation is not feasible. However, specific… Click to show full abstract

OBJECTIVES Aortic valve bypass (AVB) (apico-aortic conduit) remains an effective surgical alternative for patients in whom surgical aortic valve replacement or transcatheter aortic valve implantation is not feasible. However, specific complications include thrombus formation, possibly caused by stagnation arising from flow competition between the antegrade and retrograde flow, but this has not been fully investigated. The aim of this study was to analyse flow characteristics after AVB and to elucidate mechanisms of intra-aortic thrombus using computational fluid dynamics (CFD). METHODS Flow simulation was performed on data obtained from a 73-year-old postoperative AVB patient. Three-dimensional cine phase-contrast magnetic resonance imaging at 3 Tesla was used to acquire flow data and to set up the simulation. The vascular geometry was reconstructed using computed tomography angiograms. Flow simulations were implemented at various ratios of the flow rate between the ascending aorta and the graft. Results were visualized by streamline and particle tracing. RESULTS CFD demonstrated stagnation in the ascending aorta-arch when retrograde flow was dominant, indicating that the risk of thrombus formation exists in the ascending arch in cases with severe aortic stenosis and/or poor left ventricular function. Meanwhile, stagnation was observed in the proximal descending aorta when the antegrade and retrograde flow were equivalent, suggesting that the descending aorta is critical when aortic stenosis is not severe. CONCLUSIONS Flow stagnation in the aorta which may cause thrombus was observed when retrograde flow was dominant and antegrade/retrograde flows were equivalent. Our results suggest that anticoagulants might be recommended even in patients who receive biological valves.

Keywords: using computational; aortic valve; retrograde flow; flow competition; valve; valve bypass

Journal Title: Interactive cardiovascular and thoracic surgery
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.