OBJECTIVES Pacemakers and implantable cardioverter defibrillators have become more common in younger individuals, owing to broader indications and technological advances. Our goal was to report our long-term experience of implanting… Click to show full abstract

OBJECTIVES Pacemakers and implantable cardioverter defibrillators have become more common in younger individuals, owing to broader indications and technological advances. Our goal was to report our long-term experience of implanting cardiac devices in young adults via a subaxillary approach with a hidden single incision, to minimize the aesthetic impact of the device. METHODS From 2003 to 2012, 23 patients underwent cardiac device implantation via a subaxillary approach while they were under general anaesthesia. The axillary vein was punctured under contrast-medium radiological guidance. The devices were positioned into the pocket under the pectoralis major muscle and over the fascia that envelopes the pectoralis minor muscle, through a lateral surgical access along the midaxillary line. RESULTS Twenty-two single- and dual-chamber implantable cardioverter defibrillator and 1 dual-chamber pacemaker were implanted (mean age 32.2 ± 13.4 years). All procedures were successfully performed without complications; overall hospitalization after implantation was 3.3 days. During mean a follow-up of 65 ± 18 months, no deaths, infections or device migrations occurred. Two ventricular lead dislodgements requiring repositioning occurred within 1 month, and 1 defibrillation lead fracture occurred 5 years after implantation. All patients were extremely satisfied with the aesthetic result. A mild increase in the pacing threshold (0.88 ± 0.6 V at 0.4/0.5 ms at implantation vs 1.00 ± 0.3 V at 0.4/0.5 ms at 2-year follow-up, P = 0.063) and a statistically significant decrease in the pacing impedance (637 ± 161 ohm at implantation vs 499 ± 81 ohm at 2-year follow-up, P = 0.001) were observed, without any consequences. CONCLUSIONS The subaxillary approach is a safe, feasible technique that requires a simple surgical procedure. The implantable cardioverter defibrillator functions properly at implantation and at long-term follow-up.

Keywords: device implantation; experience; implantation; subaxillary approach

Journal Title: Interactive cardiovascular and thoracic surgery
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.