Abstract Background Isavuconazole is an antifungal drug used for treatment of invasive fungal infections. Critically ill COVID-19 and influenza patients require extracorporeal membrane oxygenation (ECMO) in cases with severe acute… Click to show full abstract
Abstract Background Isavuconazole is an antifungal drug used for treatment of invasive fungal infections. Critically ill COVID-19 and influenza patients require extracorporeal membrane oxygenation (ECMO) in cases with severe acute respiratory distress syndrome and have risk factors for invasive pulmonary aspergillosis. Little is known about isavuconazole plasma concentrations during ECMO. Objectives To determine isavuconazole plasma concentrations in seven patients treated with intravenous isavuconazole under ECMO and the influence of the ECMO circuit immediately after the first isavuconazole dose. Methods Critically ill patients treated with isavuconazole (standard doses) and ECMO were included in this study. Sixty-four blood samples used for measurement of isavuconazole concentrations were collected at several timepoints starting 2 h after the first isavuconazole dose up to 168 h. An additional 27 blood samples were drawn from the inflow and outflow line of the membrane oxygenator to assess any potential isavuconazole clearance effect of the ECMO oxygenation device and the lines. Results Median isavuconazole trough levels above 1 μg/mL (min. 0.83, max. 1.73) or 2 μg/mL (min. 0.84, max. 2.97) were achieved 24 h or 96 h after the first dose of isavuconazole. The isavuconazole plasma concentrations pre (inflow line) and post (outflow line) the membrane oxygenator were directly correlated (ρ = 0.987, R2 = 0.994, P < 0.001). Post membrane oxygenator isavuconazole concentrations were directly correlated to contemporaneous samples obtained from the arterial lines of patients (ρ = 0.942, R2 = 0.945, P < 0.001). Conclusions Isavuconazole concentrations might be influenced by the higher volume of distribution due to ECMO therapy, but were not altered by the ECMO oxygenator and achieved median plasma concentrations >1 μg/mL 24 h after the first loading dose.
               
Click one of the above tabs to view related content.