LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Antimicrobial susceptibility testing of pathogens isolated from blood culture: a performance comparison of Accelerate Pheno™ and VITEK® 2 systems with the broth microdilution method

Photo from wikipedia

Abstract Objectives To compare the performance of the Accelerate Pheno™ system with that of the conventional phenotypic VITEK® 2 system for rapid antimicrobial susceptibility testing (AST) of bacterial pathogens from… Click to show full abstract

Abstract Objectives To compare the performance of the Accelerate Pheno™ system with that of the conventional phenotypic VITEK® 2 system for rapid antimicrobial susceptibility testing (AST) of bacterial pathogens from positive blood culture (PBC) samples, based on the reference broth microdilution (BMD) method. Methods Prospectively collected PBCs that represented patient-unique bloodstream infection episodes were included. For PBC samples showing monomicrobial growth (n = 86), AST was performed using both Accelerate Pheno™ and VITEK® 2 systems directly from PBC broth. Colony isolates derived from subculture of PBC broth were then used for BMD testing. AST results were interpreted according to 2017 EUCAST breakpoints. Results The overall categorical agreement between Accelerate Pheno™ system and BMD was 92.7% (467/504) for Gram-negative organisms and 99.0% (95/96) for Gram-positive organisms, with rates for very major errors of 3.6% (6/166), major errors 2.2% (9/416) and minor errors 3.8% (23/600). The overall categorical agreement between the VITEK® 2 system and BMD was 91.7% (463/505) for Gram-negative organisms and 99.0% (97/98) for Gram-positive organisms, with rates of very major errors of 2.4% (4/169), major errors 1.0% (4/416) and minor errors 5.8% (35/603). Importantly, unlike the VITEK® 2 system, no false-susceptible results occurred with two colistin-resistant organism-growing PBCs tested using the Accelerate Pheno™ system. Conclusions Based on these findings, the Accelerate Pheno™ system can be a valid alternative for the rapid AST of Gram-negative and Gram-positive bacteria in bloodstream infections.

Keywords: system; vitek; gram; accelerate pheno; pheno

Journal Title: Journal of Antimicrobial Chemotherapy
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.