LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Evaluation of the GENE-UP ® Salmonella Method for the Detection of Salmonella Species in a Broad Range of Foods and Select Environmental Surfaces: Collaborative Study, First Action 2020.02.

Photo from wikipedia

BACKGROUND The GENE-UP®  Salmonella (SLM) assay (Performance Tested Method  SM 121802) is a PCR detection method that utilizes Fluorescence Resonance Energy Transfer hybridization probes for the rapid detection of Salmonella… Click to show full abstract

BACKGROUND The GENE-UP®  Salmonella (SLM) assay (Performance Tested Method  SM 121802) is a PCR detection method that utilizes Fluorescence Resonance Energy Transfer hybridization probes for the rapid detection of Salmonella species in foods and on environmental surfaces. OBJECTIVE The purpose of this validation was to evaluate the method's interlaboratory performance for submission to AOAC INTERNATIONAL for adoption as First Action Official Method of Analysis  SM. METHOD The GENE-UP method was evaluated in a multi-laboratory study using unpaired test portions for one food matrix, raw ground beef (80% lean). The candidate method was compared to the U.S. Department of Agriculture, Food Safety Inspection Service, Microbiology Laboratory Guidebook 4.10 reference method. An alternative confirmation procedure, using ASAP™ and CHROMID® Salmonella chromogenic agars, was included in the validation study. Fifteen collaborators from 14 laboratories participated. Three levels of contamination were evaluated: a non-inoculated control level (0 CFU/test portion), a low contamination level (∼0.7 CFU/test portion) and a high contamination level (∼2 CFU/test portion). Data were analyzed using the Probability of Detection (POD) statistical model. RESULTS The dLPODC values with 95% confidence interval for the GENE-UP Salmonella method with either alternative or traditional confirmation were: 0.00 (-0.03, 0.03), -0.02 (-0.15, 0.12), and 0.02 (-0.03, 0.09) for the non-inoculated, low and high contamination levels respectively. CONCLUSION The dLPODC results demonstrate no difference in performance between the candidate method and reference method for the matrix evaluated. HIGHLIGHTS The GENE-UP Salmonella method, with ASAP and CHROMID Salmonella, provides industry with a simplified, rapid and accurate workflow for the detection of Salmonella in a broad range of foods and select environmental surfaces.

Keywords: detection salmonella; gene salmonella; salmonella; method

Journal Title: Journal of AOAC International
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.