Mitigating Matrix Effects in LC-ESI-MS/MS Analysis of a Urinary Biomarker of Xylenes Exposure.

Photo by meindrittesauge from unsplash

Liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) with stable isotope labeled internal standards (SIL-IS) is the gold standard for quantitative analysis of drugs and metabolites in complex biological samples. Significant isotopic… Click to show full abstract

Liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) with stable isotope labeled internal standards (SIL-IS) is the gold standard for quantitative analysis of drugs and metabolites in complex biological samples. Significant isotopic effects associated with deuterium labeling often causes the deuterated IS to elute at a different retention time from the target analyte, diminishing its capability to compensate for matrix effects. In this study, we systematically compared the analytical performance of deuterated (2H) SIL-IS to non-deuterated (13C and 15N) SIL-ISs for quantifying urinary 2-methylhippuric acid (2MHA) and 4-methylhippuric acid (4MHA), biomarkers of xylenes exposure, with an LC-ESI-MS/MS assay. Analytical method comparison between IS demonstrated a quantitative bias for urinary 2MHA results, with concentrations generated with 2MHA-[2H7] on average 59.2% lower than concentrations generated by 2MHA-[13C6]. Spike accuracy, measured by quantifying analyte-spiked urine matrix and comparing the result to the known spike concentration, determined that 2MHA-[2H7] generated negatively biased urinary results of -38.4% whereas no significant bias was observed for 2MHA-[13C6]. Post-column infusion demonstrated that ion suppression experienced by 2MHA and 2MHA-[13C6] was not equally experienced by 2MHA-[2H7], explaining the negatively biased 2MHA results. Quantitation of urinary 4MHA results between IS exhibited no significant quantitative bias. These results underscore the importance of careful selection of internal standards for targeted quantitative analysis in complex biological samples.

Keywords: xylenes exposure; mitigating matrix; 2mha 13c6; analysis; matrix effects; 2mha 2h7

Journal Title: Journal of analytical toxicology
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.