LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

LC–MS-MS Determination of Cytostatic Drugs on Surfaces and in Urine to Assess Occupational Exposure

Photo by sharonmccutcheon from unsplash

Abstract The ever-increased usage of cytostatic drugs leads to high risk of exposure among healthcare workers. Moreover, workers are exposed to multiple compounds throughout their lives, leading to cumulative and… Click to show full abstract

Abstract The ever-increased usage of cytostatic drugs leads to high risk of exposure among healthcare workers. Moreover, workers are exposed to multiple compounds throughout their lives, leading to cumulative and chronic exposure. Therefore, multianalyte methods are the most suitable for exposure assessment, which minimizes the risks from handling cytostatic drugs and ensures adequate contamination containment. This study describes the development and full validation of two liquid chromatography–tandem mass spectrometry methods for the detection of gemcitabine, dacarbazine, methotrexate, irinotecan, cyclophosphamide, doxorubicinol, doxorubicin, epirubicin, etoposide, vinorelbine, docetaxel and paclitaxel in working surfaces and urine samples. The urine method is the first to measure vinorelbine and doxorubicinol. For surfaces, limits of detection (LOD) and limits of quantification (LOQ) were 5–100 pg/cm2, and linearity was achieved up to 500 pg/cm2. Inaccuracy was between −11.0 and 8.4%. Intra-day, inter-day and total imprecision were <20%, except for etoposide and irinotecan (<22.1%). In urine, LOD and LOQ were 5–250 pg/mL, with a linear range up to 1,000–5,000 pg/mL. Inaccuracy was between −3.8 and 14.9%. Imprecision was <12.4%. Matrix effect was from −58.3 to 1,268.9% and from −66.7 to 1,636% in surface and urine samples, respectively, and extraction efficiency from 10.8 to 75% and 47.1 to 130.4%, respectively. All the analytes showed autosampler (6°C/72 h), freezer (–22°C/2 months) and freeze/thaw (three cycles) stability. The feasibility of the methods was demonstrated by analyzing real working surfaces and patients’ urine samples. Contamination with gemcitabine, irinotecan, cyclophosphamide, epirubicin and paclitaxel (5–4,641.9 pg/cm2) was found on biological safety cabinets and outpatients’ bathrooms. Analysis of urine from patients under chemotherapy identified the infused drugs at concentrations higher than the upper LOQ. These validated methods will allow a comprehensive evaluation of both environmental and biological contamination in hospital settings and healthcare workers.

Keywords: urine samples; cytostatic drugs; surfaces urine; determination cytostatic; drugs surfaces; exposure

Journal Title: Journal of Analytical Toxicology
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.