Abstract Objective Using a US Food and Drug Administration (FDA) emergency use authorization (EUA) reverse transcription polymerase chain reaction (RT-PCR) method, we examined the analytic performance accuracy of saliva specimens… Click to show full abstract
Abstract Objective Using a US Food and Drug Administration (FDA) emergency use authorization (EUA) reverse transcription polymerase chain reaction (RT-PCR) method, we examined the analytic performance accuracy of saliva specimens as compared to nasopharyngeal (NP) specimens in symptomatic patients. Correlation between test results and symptoms was also evaluated. Methods Over a 5-week period in 2020, 89 matched saliva and nasopharyngeal swabs were collected from individuals exhibiting symptoms consistent with SARS-CoV-2. Specimens were tested with an FDA EUA-approved RT-PCR method, and performance characteristics were compared. Results The concordance rate between saliva and nasopharyngeal testing was 93.26%. The mean cycle threshold value of saliva when compared to the NP specimen was 3.56 cycles higher. As compared to NP swab, saliva testing demonstrates acceptable agreement but lower sensitivity. Conclusion When compared to a reference method using NP swabs, the use of saliva testing proved to be a reliable method. Self-collected saliva testing for SARS-CoV-2 allows for a viable option when trained staff or collection materials are in short supply.
               