LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Effectiveness of Copper-Impregnated Solid Surfaces on Lowering Microbial Bio-Burden Levels in an Acute Care Hospital.

Photo from wikipedia

Background Microbial bio-burden on high-touch surfaces in patient rooms may lead to acquisition of health care-associated infections in acute care hospitals. This study examined the effect of a novel copper-impregnated… Click to show full abstract

Background Microbial bio-burden on high-touch surfaces in patient rooms may lead to acquisition of health care-associated infections in acute care hospitals. This study examined the effect of a novel copper-impregnated solid material (16%-20% copper oxide in a polymer-based resin) on bacterial contamination on high-touch surfaces in patient rooms in an acute care hospital. Methods Five high-touch surfaces were sampled for aerobic bacterial colonies (ABCs) 3 times per day over a 3-day period in 16 rooms with copper installed and 16 rooms with standard noncopper laminate installed on high-touch surfaces. A Bayesian multilevel negative binomial regression model was used to compare ABC plate counts from copper-impregnated surfaces with standard hospital laminate surfaces. Results The mean and median (interquartile range [IQR]) ABC counts from copper-impregnated surfaces were 25.5 and 11 (4-27), and for standard hospital laminate surfaces they were 60.5 and 29 (10-74.3). The negative binomial regression model-estimated incidence rate for ABC counts on plates taken from copper-impregnated surfaces was 0.40 (0.21-0.70) times the incidence rate of ABC counts on plates taken from standard hospital laminate surfaces. Conclusions Copper-impregnated solid surfaces may reduce the level of microbial contamination on high-touch surfaces in patient rooms in the acute care environment, as our study demonstrated a decline in microbial bio-burden on samples taken from copper-impregnated compared with standard hospital laminate high-touch surfaces.

Keywords: high touch; copper impregnated; touch surfaces; copper; hospital; care

Journal Title: Open forum infectious diseases
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.