LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

It’s Not You, It’s SOSA: A Case Study on Breaking Up With an FDA-Cleared Susceptibility Testing System’s Oxacillin Results for Staphylococcus spp. Other Than S. aureus and S. lugdunensis

Photo by mykjohnson from unsplash

Abstract Background In 2021, the Clinical and Laboratory Standards Institute revised its susceptible oxacillin minimum inhibitory concentration (MIC) breakpoint for Staphylococcus spp. other than S. aureus and S. lugdunensis (SOSA)… Click to show full abstract

Abstract Background In 2021, the Clinical and Laboratory Standards Institute revised its susceptible oxacillin minimum inhibitory concentration (MIC) breakpoint for Staphylococcus spp. other than S. aureus and S. lugdunensis (SOSA) from  ≤0.25 to  ≤0.5 µg/mL. Here, we describe the response to this breakpoint change, which at the time of this study was not yet recognized by the US Food and Drug Administration (FDA), in our laboratory, where the primary method for antimicrobial susceptibility testing (AST) of SOSA is VITEK 2. VITEK 2 uses the Automated Expert System (AES) to integrate the results of oxacillin MIC and cefoxitin screen tests into a final interpretation; our laboratory also adjudicates discordant oxacillin and cefoxitin results using a PBP2a test. Methods We retrospectively reviewed and assessed the yield of PBP2a testing for 189 SOSA isolates with discordant (when applying the FDA susceptible oxacillin breakpoint of ≤0.25 µg/mL) VITEK 2 oxacillin and cefoxitin results, and then prospectively incorporated PBP2a testing for isolates with oxacillin MICs of 0.5 µg/mL and positive cefoxitin screens into our algorithm. Results Compared with accepting the VITEK 2 AES interpretation, PBP2a testing substantially improved the accuracy of mecA-mediated resistance classification in both scenarios, especially for the ∼4.7% of isolates with oxacillin MICs ≤0.5 µg/mL and positive cefoxitin screens. Conclusions Although detection of mecA or PBP2a is the gold standard for assessment of β-lactam resistance in staphylococci, targeting a subset of isolates for mecA or PBP2a testing based on phenotypic AST results that predict an increased risk of misclassification may be a pragmatic, labor- and cost-saving approach.

Keywords: pbp2a testing; aureus lugdunensis; staphylococcus spp; cefoxitin; susceptibility testing; spp aureus

Journal Title: Open Forum Infectious Diseases
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.