LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

PEDIATRIC HEAD CT EXPOSURE DOSES IN TUNISIA: A PILOT STUDY TOWARDS THE ESTABLISHMENT OF NATIONAL DIAGNOSTIC REFERENCE LEVELS

Photo by aiony from unsplash

&NA; The purpose of this study was to assess and analyze the radiation doses during head pediatric CT from different CT units within six Tunisian hospitals representing different geographic regions… Click to show full abstract

&NA; The purpose of this study was to assess and analyze the radiation doses during head pediatric CT from different CT units within six Tunisian hospitals representing different geographic regions in order to optimize the dose given and minimize the radiology risk to this category of patients and towards the derivation of national diagnostic reference levels. Patient data and exposure parameters were collected for four age groups (<1, 1‐5, 5‐10 and 10‐15 y). Clinical protocols and exposure settings were analyzed. Doses were collected in terms of CTDIvol and DLP values. Effective and Organ doses to specific radiosensitive organs were estimated using the Monte Carlo simulation software ‘Impact CTDosimetry’. Results showed large variations in CT protocols and doses between different radiology departments. CTDIvol and DLP values demonstrated a broad range between the CT units and between the axial and helical scan techniques in the same unit. CTDI vol values were estimated to be 24.9, 31.7, 45.5 and 47.8 mGy for <1, 1‐5, 5‐10 and 10‐15 y age groups, respectively. In term of DLP, median values were ˜346, 528, 824, 897 mGy cm for the same age groups, respectively. Effective dose ranged from 1.4 to 5 mSv. Dose values were comparable with those reported in the literature. The study shows an evident need for continuous training of staff in radiation protection concepts, especially within the regional hospitals, emphasizes the importance of the production and the update of recommendations and good practice guidelines using interdisciplinary working groups and opens the way for the establishment of national DRLs.

Keywords: establishment national; reference levels; study; radiology; diagnostic reference; national diagnostic

Journal Title: Radiation Protection Dosimetry
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.