LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Automatic analysis of muscular activity in the flexor digitorum superficialis muscles: a fast screening method for rapid eye movement sleep without atonia

Photo from wikipedia

Abstract Study objectives To identify a fast and reliable method for rapid eye movement (REM) sleep without atonia (RWA) quantification. Methods We analyzed 36 video-polysomnographies (v-PSGs) of isolated REM sleep… Click to show full abstract

Abstract Study objectives To identify a fast and reliable method for rapid eye movement (REM) sleep without atonia (RWA) quantification. Methods We analyzed 36 video-polysomnographies (v-PSGs) of isolated REM sleep behavior disorder (iRBD) patients and 35 controls’ v-PSGs. Patients diagnosed with RBD had: i) RWA, quantified with a reference method, i.e. automatic and artifact-corrected 3-s Sleep Innsbruck Barcelona (SINBAR) index in REM sleep periods (RSPs, i.e. manually selected portions of REM sleep); and ii) v-PSG-documented RBD behaviors. We quantified RWA with other (semi)-automated methods requiring less human intervention than the reference one: the indices proposed by the SINBAR group (the 3-s and 30-s phasic flexor digitorum superficialis (FDS), phasic/”any”/tonic mentalis), and the REM atonia, short and long muscle activity indices (in mentalis/submentalis/FDS muscles). They were calculated in whole REM sleep (i.e. REM sleep scored following international guidelines), in RSPs, with and without manual artifact correction. Area under curves (AUC) discriminating iRBD from controls were computed. Using published cut-offs, the indices’ sensitivity and specificity for iRBD identification were calculated. Apnea-hypopnea index in REM sleep (AHIREM) was considered in the analyses. Results RWA indices from FDS muscles alone had the highest AUCs and all of them had 100% sensitivity. Without manual RSP selection and artifact correction, the “30-s phasic FDS” and the “FDS long muscle activity” had the highest specificity (85%) with AHIREM < 15/h. RWA indices were less reliable when AHIREM≥15/h. Conclusions If AHIREM<15/h, FDS muscular activity in whole REM sleep and without artifact correction is fast and reliable to rule out RWA.

Keywords: sleep without; rem sleep; activity; method; sleep

Journal Title: Sleep
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.