LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

PS-C08-1: ACCURACY OF CUFF BLOOD PRESSURE AND SYSTOLIC BLOOD PRESSURE AMPLIFICATION

Photo from wikipedia

Objective: Automated cuff measured blood pressure (BP) is the global standard used for diagnosing hypertension, but there are concerns regarding the accuracy of the method. Individual variability in systolic BP… Click to show full abstract

Objective: Automated cuff measured blood pressure (BP) is the global standard used for diagnosing hypertension, but there are concerns regarding the accuracy of the method. Individual variability in systolic BP (SBP) amplification from central (aorta) to peripheral (brachial) arteries could be related to the accuracy of cuff BP, but this has never been determined and was the aim of this study. Methods: Cuff BP and invasive brachial BP were recorded in 755 participants (73% male, aged 64 ± 11 years) receiving coronary angiography at six independent research sites (using seven different automated cuff BP devices). SBP amplification was recorded invasively by catheter and defined as brachial SBP minus aortic SBP. Results: Compared with invasive brachial SBP, cuff SBP was significantly underestimated (130 ± 18 mmHg vs. 138 ± 22 mmHg, p < 0.001). The level of SBP amplification varied significantly among individuals (mean ± SD, 7.3 ± 9.1 mmHg; interquartile range, -2.4 to 12.3 mmHg) and was similar to level of difference between cuff and invasive brachial SBP (mean difference -7.6 ± 11.9 mmHg). SBP amplification explained most of the variance in accuracy of cuff SBP (R2 = 19%). The accuracy of cuff SBP was greatest among those participants in the lowest SBP amplification quintiles (ptrend< 0.001). After cuff BP values were corrected for SBP amplification, there was a significant improvement in the mean difference from the intra-arterial standard (p < 0.0001) and in the accuracy of hypertension classification according to 2017 ACC/AHA guideline thresholds (p = 0.005). Conclusions: The accuracy of automated cuff BP is markedly influenced by individual variability in SBP amplification. This knowledge can help improve the accuracy of cuff BP.

Keywords: blood pressure; accuracy; amplification; cuff; sbp amplification

Journal Title: Journal of Hypertension
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.