LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures.

Photo by kellysikkema from unsplash

OBJECTIVE Medial calcar buttress plating combined with lateral locked plating is biomechanically tested against isolated lateral locked plating in synthetic humeri models for the treatment of proximal humerus fractures. METHODS… Click to show full abstract

OBJECTIVE Medial calcar buttress plating combined with lateral locked plating is biomechanically tested against isolated lateral locked plating in synthetic humeri models for the treatment of proximal humerus fractures. METHODS Proximal humerus fractures (OTA/AO type 11-A2.1) were manufactured in 10 pairs of Sawbones humeri models (Sawbones, Pacific Research Laboratories, Vashon Island, WA). Specimen were randomly assigned and instrumented with either medial calcar buttress plating combined with lateral locked plating (CP) or isolated lateral locked plating (LP).Non-destructive torsional and axial load tests were performed to evaluate construct stiffness. Large-cycle axial tests were conducted followed by destructive ramp-to-failure tests. Cyclic stiffness was compared in both non-destructive and ultimate failure loads. Failure displacement was recorded and compared between groups. RESULTS The addition of medial calcar buttress plating to lateral locked plating constructs significantly increased the axial (p < 0.01) and torsional (p < 0.01) stiffness of the construct compared with isolated lateral locked plating by 95.56 % and 37.46 % respectively. All models demonstrated greater axial stiffness (p < 0.01) following 5,000 cycles of axial compression, not dependent on fixation method. During destructive testing, the CP construct withstood 45.35 % larger load (p < 0.01) and congruently exhibited 58 % less humeral head displacement (p=0.02) before failure when compared to the LP construct. CONCLUSION This study demonstrates the biomechanical superiority of medial calcar buttress plating when combined with lateral locked plating as compared with isolated lateral locked plating of OTA/AO type 11-A2.1 proximal humerus in synthetic humeri models.

Keywords: medial calcar; lateral locked; isolated lateral; locked plating; proximal humerus

Journal Title: Journal of orthopaedic trauma
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.