LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Teaching a New Dog Old Tricks: Ultrafast Liquid Chromatography/Tandem-Mass Spectrometry Analysis of Nine ß-Lactam Antibiotics for Improved Therapeutic Drug Monitoring

Photo from wikipedia

Supplemental Digital Content is Available in the Text. Background: Therapeutic drug monitoring (TDM) of β-lactam antibiotics provides critical knowledge in hospital intensive care unit environments to support dosing within the… Click to show full abstract

Supplemental Digital Content is Available in the Text. Background: Therapeutic drug monitoring (TDM) of β-lactam antibiotics provides critical knowledge in hospital intensive care unit environments to support dosing within the narrow window between therapeutic failure and toxicity. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the most suitable analytical technique for these drugs; however, clinicians, patients, and laboratories would benefit from shortening the timeframe between the collection of samples and reporting of results. Methods: The authors developed a very rapid LC-MS/MS method for 9 β-lactam antimicrobial drugs on a commercial core–shell reverse-phase LC column by exploiting the performance of such stationary phase materials at a high mobile-phase linear velocity and using a simple flow split to optimize ionization conditions in the mass spectrometer ion source. The method's performance was assessed using a currently validated routine LC-MS/MS assay performed on the same instrument. Results: Routine ß-lactam assays were reduced from >6 minutes per sample to less than 2 minutes with improved chromatographic resolution, while still maintaining acceptable analytical performance (average correlation coefficient: 0.99670, interday imprecision: 2.0%–10.8%, and bias: –1.68%), hence generating results in agreement with an existing validated method for patient and quality assurance program samples. Conclusions: Time-critical results, such as those for β-lactam antimicrobials, may be reported by the TDM laboratory several hours earlier than current methods allow, providing improved patient care and generating capacity on LC-MS/MS instruments for larger batch sizes and/or additional assays. The simple-to-implement technique demonstrated in this study may be applicable to other TDM assays or any LC-MS/MS method where faster turnaround times are desirable.

Keywords: chromatography tandem; liquid chromatography; therapeutic drug; lactam antibiotics; drug monitoring

Journal Title: Therapeutic Drug Monitoring
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.