LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparison of three office blood pressure measurement techniques and their effect on hypertension prevalence in the general population.

Photo from wikipedia

OBJECTIVES There is an ongoing controversy about the magnitude of the difference between unattended automated office blood pressure (AOBP) and conventional office blood pressure (BP). The aim of our study… Click to show full abstract

OBJECTIVES There is an ongoing controversy about the magnitude of the difference between unattended automated office blood pressure (AOBP) and conventional office blood pressure (BP). The aim of our study was to compare unattended AOBP with both auscultatory BP and oscillometric attended AOBP in an epidemiological setting. METHODS In 2588 participants of the Czech post-MoNItoring of CArdiovascular Disease study (a randomly selected 1% representative population sample aged 25-64 years, mean age 48 ± 11 years, 47.5% males), BP was measured using an AOBP device unattended, auscultatory mercury sphygmomanometer and an oscillometric attended AOBP device. RESULTS On average, auscultatory BP was 10.6/5.6 mmHg higher than unattended AOBP. Similarly, oscillometric attended AOBP was 9.9/3.4 mmHg higher than unattended AOBP, while the mean difference between attended oscillometric AOBP and auscultatory BP was 0.8/2.1 mmHg. Unattended systolic AOBP of 127 mmHg corresponded to SBP of 140 mmHg measured by a conventional sphygmomanometer. The prevalence of hypertension varied depending on the measurement technique and ranged from 31.5 to 40.1%. Reasonable agreement in hypertension diagnosis was observed with unattended AOBP cut-off at least 130/85 mmHg when compared with both auscultatory (McNemar P = 0.07, kappa 0.819) and attended oscillometric AOBP (McNemar P = 0.46, kappa 0.852) thresholds of at least 140/90 mmHg. CONCLUSION Unattended automated office SBP is on average 10 mmHg lower than the office auscultatory or attended AOBP values. In epidemiological settings, a threshold of unattended AOBP at least 130/85 mmHg should make comparison of hypertension prevalence possible with studies using auscultatory techniques and cut-off values of 140/90 mmHg.

Keywords: office; blood pressure; office blood; hypertension; unattended aobp

Journal Title: Journal of Hypertension
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.