LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Measuring Workload with Paired Detectors.

Photo by irishinechka from unsplash

Linear accelerator workloads for each available photon energy are important quantities to know for radiation safety considerations, and presented is a technique to measure the workload using paired detectors. The… Click to show full abstract

Linear accelerator workloads for each available photon energy are important quantities to know for radiation safety considerations, and presented is a technique to measure the workload using paired detectors. The signals from the two detectors can give sufficient information to separate the signal contributions from 6 and 18 MV photon fields and, combined with a signal-per-monitor-unit calibration factor, yields the number of monitor units delivered for each energy. CR-39 NTD is a neutron detector chosen for its ability to discriminate between 6 MV and 18 MV radiation fields. TLD-100 is a detector responsive to both 6 MV and 18 MV fields. These appeared to be a good choice for a detector pair. This experiment had both failures and successes to report. The CR-39 NTD and TLD-100 were not a successful pairing. The CR-39 NTD signals saturated under this experiment's exposure conditions. The TLD-100 had a combination of detector noise and detector sensitivity that made extracting the 6 MV signal from the total signal impractical, unless the total exposure was overwhelmingly 6 MV. Nevertheless, the TLD-100 proved to be excellent for determining workloads when it was exposed to a single energy with 1% accuracy and 3% precision. The theory and data analysis showed the importance of understanding the noise contributions for the more general problem of pairing any two detector types. This experiment indicated the TLD-100 could be an excellent detector choice if paired with a suitable second detector.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

Keywords: paired detectors; tld 100; detector; measuring workload; workload paired

Journal Title: Health Physics
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.