The Effects of Radiation and Emitted Light Transport on the Positional Response of 11 cm × 42.5 cm × 5.5 cm NaI(Tl) Detectors.

Photo from wikipedia

Experiments were performed with 30 11 cm × 42.5 cm × 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point… Click to show full abstract

Experiments were performed with 30 11 cm × 42.5 cm × 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point sources of Am, Cs, Co, and Ba positioned on lines parallel and perpendicular to the long axis of the crystal along both the narrow and wide detector faces as well as at different distances from them. A greater density of positions was sampled at the ends of the detector, and repeated measurements were made to examine potential gain drifts during the experiment. Spectroscopic peak counts, spectroscopic pulse heights, and net counts were analyzed. Empirical equations were fit to the aforementioned data for each specific source energy as a function of source position. In addition, a Monte Carlo radiation transport code was used to simulate the expected positionally variable response based solely upon radiation absorption. The simulated radiation transport efficiency functions were compared to the experimental data. The effects of the geometric radiation efficiency, the attenuation and scattering of emitted light within the scintillation crystal, and combined effects such as nonuniformity of the photomultiplier tube, photocathode response, and crystal irregularities were then distinguished. Functions describing each effect were derived. The results suggest potential new corrections to data obtained with large scintillation detectors as well as a novel approach to partial positional gamma-ray detection with minimal collimation, given that the energy resolution is within reason for particular photopeaks.

Keywords: response; positional response; transport; radiation; emitted light; nai detectors

Journal Title: Health Physics
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.