LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Simple Single-Pass Technique for Ultrathin Descemet Stripping Automated Endothelial Keratoplasty: A Pilot Study

Photo by nci from unsplash

Purpose: To assess intraoperative and postoperative graft thickness (GT) after donor deturgescence for ultrathin Descemet stripping automated endothelial keratoplasty and to evaluate visual outcomes, endothelial cell density, and patient satisfaction… Click to show full abstract

Purpose: To assess intraoperative and postoperative graft thickness (GT) after donor deturgescence for ultrathin Descemet stripping automated endothelial keratoplasty and to evaluate visual outcomes, endothelial cell density, and patient satisfaction at 1 year. Methods: Prospective interventional case series of patients with Fuchs endothelial dystrophy, Fuchs endothelial dystrophy and cataract, and pseudophakic bullous keratopathy (n = 12 grafts). The donor cornea was allowed to thin out by simple evaporation on an artificial anterior chamber, to the required precut thickness, before a single microkeratome pass. GT after microkeratome cut, at 1 week, 1, 3, 6, and 12, months was measured. Early Treatment Diabetic Retinopathy Study (ETDRS) best-corrected visual acuity, Pelli–Robson contrast sensitivity, endothelial cell density, and score on the visual function questionnaire (VFQ-25) were assessed. Results: Mean intraoperative postmicrokeratome cut GT was 78.9 ± 33.3 &mgr;m. Mean GT at 1 week, 1, 3, 6, and 12 months was 70.7, 70.9, 62.8, 66.5, and 58.9 &mgr;m, respectively. Mean initial donor corneal thickness was 647 ± 67 &mgr;m, and mean precut thickness was 526 ± 4.5 &mgr;m (mean thinning time: 17 min). Best-corrected visual acuity at 1 week, 1, 3, 6, and 12 months was 68.8, 76.9, 76.3, 76.9, and 78.6 letters with 9-letter gain at 12 months (P = 0.02). Mean endothelial cell loss at 3, 6, and 12 months was 36.8% ± 6.75%, 37.2% ± 8%, and 37.9% ± 9.75% loss, respectively. At 1 year, 83.3% of patients achieved ≥20/40 (6/12) and 66.7% of patients achieved ≥20/32 (6/9.5). VFQ-25 testing showed an improvement in the visual function. Conclusions: This pilot study demonstrates a simple graft deturgescence technique that reproducibly creates ultrathin grafts without donor wastage.

Keywords: endothelial keratoplasty; automated endothelial; ultrathin descemet; study; stripping automated; descemet stripping

Journal Title: Cornea
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.