LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Anterior Segment Parameters in Patients With Wilson Disease

Photo from wikipedia

Purpose: To investigate anterior segment parameters in patients with Wilson disease (WD). Methods: In this cross-sectional study, 22 patients with WD (study group) and 22 healthy subjects (control group) were… Click to show full abstract

Purpose: To investigate anterior segment parameters in patients with Wilson disease (WD). Methods: In this cross-sectional study, 22 patients with WD (study group) and 22 healthy subjects (control group) were enrolled. Each participant underwent a comprehensive ophthalmic assessment including best-corrected visual acuity, slit-lamp biomicroscopy, fundus examination, and intraocular pressure. Anterior segment parameters were measured by the Sirius anterior segment analyzer system (Costruzione Strumenti Oftalmici, Florence, Italy). Results: Mean central corneal thickness was 522 ± 47 &mgr;m in the study group and 568 ± 37 &mgr;m in the control group (P < 0.001). Mean flat keratometry was 42.4 ± 1.7 diopter (D) in the study group and 41.5 ± 1.16 D in the control group (P = 0.011); mean steep keratometry was 43.4 ± 2.0 and 42.4 ± 1.4 D in the study and control groups, respectively (P = 0.025). The anterior corneal elevation value was 5.5 ± 3.2 &mgr;m in the study group and 4.08 ± 2.2 &mgr;m in the control group (P = 0.029); the mean posterior corneal elevation value was 15.1 ± 6.0 and 10.1 ± 4.1 &mgr;m in the study and control groups, respectively (P = 0.002). The mean anterior chamber depth was 2.97 ± 0.3 &mgr;m in the study group and 3.16 ± 0.3 &mgr;m in the control group (P = 0.01); the mean horizontal visible iris diameter was 11.9 ± 0.4 and 12.2 ± 0.4 &mgr;m in the study and control groups, respectively (P = 0.001). Conclusions: This study indicates that patients with WD have differences in the anterior segment parameters including central corneal thickness, keratometric values, anterior and posterior elevations, horizontal visible iris diameter, and anterior chamber depth when compared with healthy controls.

Keywords: segment parameters; control; anterior segment; group; study

Journal Title: Cornea
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.