Minimizing Endothelial Cell Loss Caused by Orientation Stamps on Preloaded Descemet Membrane Endothelial Keratoplasty Grafts

Purpose: To quantify endothelial cell loss (ECL) caused by orientation stamps on prestripped and preloaded Descemet membrane endothelial keratoplasty (DMEK) grafts, and to examine a method for reducing ECL using… Click to show full abstract

Purpose: To quantify endothelial cell loss (ECL) caused by orientation stamps on prestripped and preloaded Descemet membrane endothelial keratoplasty (DMEK) grafts, and to examine a method for reducing ECL using a smaller stamp. Methods: Ten prestripped and 10 preloaded DMEK grafts were prepared with S-stamps. Ten additional preloaded DMEK grafts were prepared with both an S-stamp and a smaller F-stamp in different paracentral areas of the graft. The footprint of each stamp was measured using ink on cardstock. DMEK grafts were stored in viewing chambers filled with 20 mL of Optisol-GS for 3 days at 4°C. ECL was quantified using Calcein-AM staining and FIJI Weka Segmentation. Results: S-stamps on prestripped DMEK grafts contributed an average ECL of 1.1% ± 0.5% (range: 0.6%–2.2%) toward total graft damage, whereas S-stamps on preloaded DMEK grafts contributed approximately twice that amount (average ECL: 2.0% ± 0.7%, range: 1.3%–3.1%, P = 0.004). Overall ECL for prestripped grafts (average: 7.1% ± 3.3%, range: 3.3%–13.7%) and preloaded grafts (average: 11.3% ± 4.2%, range: 6.9%–19.4%) was similar to previous reports. The footprint of the S-stamp was approximately 45% larger than that of the F-stamp. In 10 preloaded grafts marked with both stamps, the S-stamp caused an average ECL of 1.9% ± 0.6% (range: 1.2%–3.2%), whereas the smaller F-stamp caused an average ECL of 1.0% ± 0.2% (range: 0.8%–1.4%, P = 0.0002). Conclusions: Loss of endothelial cells associated with graft-stamping was greater in preloaded tissue than in prestripped tissue and was less with a smaller F-stamp than with a larger S-stamp. Using a smaller stamp could help minimize ECL in prestripped and preloaded DMEK grafts.

Keywords: smaller stamp; loss; dmek grafts; range; stamp

Journal Title: Cornea
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.