LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Scheimpflug Corneal Densitometry Changes After the Intrastromal Corneal Ring Segment Implantation.

Photo by nickkarvounis from unsplash

PURPOSE To investigate the changes in corneal backward scattering using Scheimpflug tomography (densitometry) 6 months after intrastromal corneal ring segments (Keraring) implant for keratoconus and to correlate with clinical results.… Click to show full abstract

PURPOSE To investigate the changes in corneal backward scattering using Scheimpflug tomography (densitometry) 6 months after intrastromal corneal ring segments (Keraring) implant for keratoconus and to correlate with clinical results. METHODS Along with standard ophthalmic examination, Scheimpflug tomography using Pentacam HR was performed to document corneal densitometry and corneal shape. A densitometry map was displayed using grayscale units (GSUs) ranging from 0 to 100 (minimum to maximum light scattering) in 4 concentric annuluses: central 2-, 2- to 6-, 6- to 10-, 10- to 12-, and total 12-mm corneal diameter and at 3 different depths: anterior 120 μm, posterior 60 μm, middle (varying accordingly to the total thickness), and total thickness. RESULTS The changes in mean corneal densitometry values for anterior, central, and posterior layers were 3.82 ± 3.13, 2.70 ± 1.78, and 1.68 ± 1.52 GSU, respectively, and for annuluses of 0 to 2, 2 to 6, 6 to 10, and 10 to 12 mm were 2.96 ± 2.60, 4.53 ± 2.28, 2.09 ± 1.74, and 0.45 ± 3.93 GSU, respectively. The mean values increased for all corneal layers (P < 0.05), except in the peripheral 10- to 12-mm annulus (P> 0.05). The highest increase was in the annulus 2 to 6 mm of the anterior layer (5.72 ± 3.70 GSU). Changes in the mean densitometry showed a significant correlation with the mean of average keratometry changes only for the front corneal surface and changes in the Q-values for both corneal surfaces in the 2- to 6-mm annulus for all layers. CONCLUSIONS Significant increase in the corneal densitometry mainly in the anterior 2- to 6-mm annulus of the cornea is associated with the position of the ring segment implant. More studies are needed to elucidate the relevance of such findings.

Keywords: ring segment; densitometry; corneal densitometry; corneal; intrastromal corneal; corneal ring

Journal Title: Cornea
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.